Denyo Avr Nta-5a-2db Manual 💫

| Item | Description | |------|-------------| | Model | Denyo AVR NTA‑5A‑2DB | | Type | Automatic Voltage Regulator (AVR) for diesel generators | | Primary Use | Maintains stable output voltage (±5 % tolerance) under varying load conditions | | Power Rating | 5 kVA (5 kW) – suitable for small‑to‑medium commercial or industrial generators | | Input Voltage | 380 V ± 10 % (three‑phase) | | Output Voltage | 220 V ± 5 % (three‑phase) | | Frequency | 50 Hz (± 1 %) | | Operating Temperature | –10 °C to +50 °C | | Protection Features | Over‑voltage, under‑voltage, over‑frequency, under‑frequency, short‑circuit, overload, thermal overload, loss‑of‑excitation |

Keep a maintenance log that includes date, operating hours, observations, and corrective actions. | Fault Code / Symptom | Likely Cause | Recommended Action | |----------------------|--------------|--------------------| | E1 – Over‑voltage | Input voltage too high, regulator malfunction, or sensor drift. | Verify generator voltage at the AVR input. If within spec, reset the AVR (power‑cycle). If fault persists, replace the voltage sensor or the AVR. | | E2 – Under‑voltage | Input voltage too low, fuel‑starvation, or loose input connections. | Check generator speed and fuel supply. Tighten input terminals. | | E3 – Over‑frequency | Engine speed exceeds 50 Hz set‑point. | Inspect governor and speed sensor. | | E4 – Under‑frequency | Engine speed too low. | Same as above – check governor, fuel pump. | | E5 – Over‑current / Overload | Load exceeds 5 kVA, or short circuit on output side. | Reduce load, inspect load busbars for faults, check protective devices. | | E6 – Thermal overload | Internal temperature > 85 °C (fan failure, blocked ventilation). | Clean ventilation, verify fan operation, replace fan if needed. | | No display / dead unit | Power supply (24 VDC) missing or dead battery. | Confirm 24 VDC present. Replace control‑power source or battery. | | Communication failure (RS‑485) | Wrong baud rate, missing termination, wiring error. | Verify settings on master device, add 120 Ω termination at the far end, re‑check wiring polarity. | | Intermittent voltage | Loose terminal, damaged cable, or aging voltage sensor. | Tighten all connections, replace suspect cables, consider sensor replacement. | denyo avr nta-5a-2db manual